Choosing the Right Thickness of Exterior Foam
Rigid foam must be thick enough to prevent condensation on the roof sheathing.
When combining exterior foam insulation with fiberglass, cellulose, or mineral-wool roof insulation, the foam layer must be thick enough to keep the sheathing temperature above the dew point. Otherwise, water vapor can condense on the back side of the sheathing, elevating the moisture content of the materials and possibly resulting in mold and rot. The problem is compounded because the exterior foam layer and most common roofing materials prevent drying to the exterior. To prevent wet sheathing, the IRC requires builders to use Table R806.5 to determine the foam thickness to prevent condensation. Warmer climates require less foam. Colder climates need a thicker layer. See the table below, and read more about choosing the right type of exterior foam inMichael Maines‘ article,“Get the Right Rigid Foam,”inFHB# 273。
TABLE R806.5 | |
Climate Zone | Minimum Rigid Board on Air-Impermeable Insulation R-Value |
2B and 3B tile roof only | 0 (none required) |
1, 2A, 2B, 3A, 3B, 3C | R-5 |
4C | R-10 |
4A, 4B | R-15 |
5 | R-20 |
6 | R-25 |
7 | R-30 |
8 | R-35 |
For more information about why thickness matterswhen choosing rigid-foam insulation, read Martin Holladay’s article,Calculating the Minimum Thickness of Rigid Foam Sheathingat GreenBuildingAdvisor.com.
From Fine Homebuilding #273